Gas Analysis Equipment Testo 350X |
| Parameter |
Range |
Accuracy |
| Oxygen O2 |
0-25% |
Better than +/- 0.8% of f.s.v. |
| Carbon Monoxide CO |
0-10000 ppm |
Better than +/- 0.5% of f.s.v |
| Nitric Oxide NO |
0-3000 ppm |
Better than +/- 0.5% of f.s.v |
| Nitrogen Dioxide NO2 |
0-500 ppm |
Better than +/- 0.5% of f.s.v |
| Sulpher Dioxide SO2 |
0-5000 ppm |
Better than +/- 0.5% of f.s.v |
| Differential Pressure |
+/- 200hPa and +/- 40hPa |
+/- 1.5% of m.v. |
| Stack gas velocity with Pitot Tube |
0-80 m/s |
- |
| Stack Gas temperature |
0 -1200 Centigrade |
+/- 0.5 of m.v. |
|
Environment Analysis Equipment |
| Parameter |
Range |
Accuracy |
| Air Velocity (Hot Bulb) |
0-10 m/s |
+/- (0.03m/s +5% of m.v) |
| Air Velocity (Hot Wire) |
0-20 m/s |
+/- (0.03m/s +5% of m.v) |
| Air Velocity (Vane Anemometer) |
0.4-60 m/s (-30 to + 140 Centigrade) |
+/- (0.2m/s +1% of m.v) |
| Relative Humidity |
0-100% rh (-20 to + 70 Centigrade) |
+/- 2% rh |
| Differential Pressure |
+/- 200hPa and +/- 40hPa |
+/- 1.5% of mv |
| Temperature |
-200 to 1760 Centigrade |
Dependent on probe |
|
Software & Work Tools |
Results from testing and monitoring are thoroughly analysed using WISenvironmental's bespoke and unique software tools, many of which have been developed in house and cannot be found elsewhere. All analysis and reports are made available to the client. |
| Process Tools |
Short Description |
| Combustion Diagram |
Shows limit of combustion in diagram and where use of preheated combustion air and burner is needed. |
| VOL-Convert |
Calculate normalised gas composition and convert gas composition in different units from a known gas composition. |
| CV-Calc |
Calculate Calorific Value of boiler of feed stock using the thermal balance method; also as basis for boiler performance tests. |
| AGT-Calc |
Calculate amount of product to be used for most acid Flue Gas Cleaning processes; compares costs between different treatment options. Can be used for 1- Health Check, 2-Design purpose, 3- to compare treatment systems & 4- Due Diligence verifications. |
| COMB-Calc |
Models combustion process: Output is flue gas composition, temperatures and energy at 3 combustion stages - Can be used for Health Check or Design purpose. |
| Project Management Tools |
WISenvironmental have a number of quality assurance tools for projects which allow the managing of projects and the transparent presentation of information and work processes. Most are standard tools (such as document logs, calculation sheets, H&S risk assessment forms, etc.), not presented here. |
| Commissioning QA Tool |
Standardised method for commissioning of thermal treatment of waste plant. |
| Problem Solving Methodology |
Standardised method for onsite questions. Get relevant data to facilitate problem solving. |
|
|
 |